Ringing in Series II peripherals 3-35
DMS-100 Ringing System
35 To post the first LCM, type
> POST LCM 0 0
and press the Enter key.
36 Are the units in the LCM aliged to use RG-1?
37 To get an LCM unit to use RG-1, type
> SWRG UNIT unit_no
and press the Enter key.
where
unit_no
is the unit number you want to switch to RG-1 (0 or 1)
Example of a MAP responce:
swrg unit 1
LCM HOST 00 0 Unit 1 SWRG Passed
Perform this step for each LCM unit that needs to use RG-1.
Note:
The recommended RG assignment for the LCM is RG-0.
38 To test the ringing generator and LCM unit, type
> TST UNIT 1
and press the Enter key.
39 To busy unit 0 of the first LCM, type
> BSY UNIT 0
and press the Enter key.
If both LCM units Do
are aligned and both use RG-1 Step 38
are not aligned or both do not
use RG-1
Step 37
Comentarios a estos manuales