DMS-100 ringing overview 1-7
DMS-100 Family DMS-100 Ringing System BASE15 and up
The frequencies used in the frequency selective ringing scheme are as follows:
• harmonic ringing: 16-2/3 Hz, 25 Hz, 33-1/3 Hz, 50 Hz, 66-2/3 Hz
• synchromonic ringing (20 Hz base): 20 Hz, 30 Hz, 42 Hz, 54 Hz, 66 Hz
• synchromonic ringing (16 Hz base): 16-2/3 Hz, 30 Hz, 42 Hz, 54 Hz
• decimonic ringing: 20 Hz, 30 Hz, 40 Hz, 50 Hz, 60 Hz.
Frequency selective ringing is used by Rural Electrification Association
(REA) offices. The following figures illustrate the REA frequency selective
ringing timing for the following types of ringing:
• synchromonic
• harmonic
• decimonic
Synchromonic ringing
The following figure illustrates the relationship between the synchromonic
ringing signals and the DMS-100 ringing cycle.
Figure 1-4 Synchromonic ringing
Note: Available frequencies are 16-2/3 Hz, 20 Hz, 30 Hz, 42 Hz, 54 Hz and
66 Hz. Any four of the available six frequencies, in any order, can be
assigned to frequencies A through D: however, 16 Hz and 20 Hz can not be
used simultaneously.
(seenote)
FrequencyA
(1 party)
FrequencyB
FrequencyC
FrequencyD
ANI/coin
02345786101119
(Any available slot)
02345786101119
6s
3300HHzz
4422HHzz
5544HHzz
6666HHzz
11..9955ss
11..3355ss
11..3355ss
11..3355ss
Comentarios a estos manuales