1-38 DMS-100 ringing overview
297-1001-131 Standard 06.01 October 2000
The following table provides a summary of ringing generator power
specifications in the NTNP50 POTS 32 line card.
The following table provides a summary of the compatibility of DMS-100
ringing types.
The following table provides a summary of the compatibility of teen ringing
types.
Table 1-9 Ringing generator power specifications - NTNP50
Parameter Minimum Nominal Maximum Units
Supply Voltage
Supply Current
36
0.3
48 75
0.8
V dc
Amps
Table 1-10 Compatibility of DMS-100 ringing types
Ringing type Immediate ring Distinctive ring
Superimposed Yes (see notes 1-3) No
Coded Yes Yes
Frequency selective Yes (see note 4) No
Immediate ringing --- No
Distinctive ringing No ---
Note 1:
There can be no more than 2FRs, that is, no 4FRs, 8-party or 10-party.
Note 2:
All 6X30 DIP switch settings must be set with switch 2 and 3 on (1) and
switches 4 through 8 off (0).
Note 3:
LCMs will not support immediate ringing on frequency selective ringing
lines unless all ringing time slots have the same frequency.
Note 4:
LCMs will not support immediate ringing on superimposed ringing lines
unless all ringing time slots have the same dc offset.
Table 1-11 Compatibility of teen ringing
Ringing type Teen ringing
Immediate ringing Yes
Distinctive ringing Yes